AC / Dehumidification System High Head Pressure Alarm
I am on a service call where the ac / dehumidification/ pool heater is triggering an alarm for high head pressure. Outside the house the ground is being mixed with sand and tilled together. I find the condenser coil plugged solid not allow heat to be rejected from system. Head pressure was 470psi on 70 degree day. Therefore I clean the condenser coil. After cleaning head pressure was 330psi.
Видео AC / Dehumidification System High Head Pressure Alarm канала The HVAC Hacker
Видео AC / Dehumidification System High Head Pressure Alarm канала The HVAC Hacker
Показать
Комментарии отсутствуют
Информация о видео
Другие видео канала
Interesting AC Freon LeakBlack Ice Offensive?Boiler Leaky Air Vent RepairHVAC Hacks: Roof or Dumpster?Reset Water Heater Locked Out Ignition Failure Previously Soldered Leak on TankAC Troubleshooting Low SuperheatRemoving Nailed Hot Water BaseboardsAC Outdoor Condenser Not Turning OnCustomer Mistake Leads to Easy AC Service CallAC Water LeakOne AC Not Cooling On Hot Days Other HVAC system cooling Multiple HVACAC Blowing Warm Air Condenser Not Turning OnHVAC Hacks: Check Out Hacked In AC Filter DrierNo Ac Call Back? Compressor not RunningHVAC Troubleshooting/ Diagnosing ECM Blower Motor No Air Out Of AC VentsStarting Semi Hermetic Compressor Carlyle 06DHappy July 4th NYC/ Jersey City Firework ShowCommercial HVAC Service Survival Tip Hot Days/ Replace Contactor & BeltHVAC Tech Life Service Calls Multiple Units DownHow I Solder Vertical Copper Fittings Make Clean, Sealed, Sweat Connection