Загрузка страницы

Ramp & Soak PID Programming Tutorial, Auber SYL-23X2P Series

Two tutorial videos are available for this ramp soak controller.
For ramp soak step programming, see https://youtu.be/raxscrYmxhg​ (this video)
For parameter settings, see https://youtu.be/6h139MgGvnY​

0:21 Example 1 (basic):
C01 = 800, t01 = 3 Heat up and soak at 800 degree, total time 3 minutes
C02 = 800, t02 = 12 Soak at 800 degree for 12 minutes
C03 = 800, t03 = -121 Stop program, turn off heater, cool down

2:56 Safety start feature
4:57 Command for special events

5:40 Example 2 (advance):
C01 = 70, t01 = 3 Ramp up from 70 to 400 degree in 3 minutes
C02 = 400, t02 = 6 Maintain at 400 degree for 6 minutes
C03 = 400, t03 = 12 Cool down from 400 to 160 degree in 12 minutes
C04 = 160, t04 = -65 Manually activate AL1 relay and go to step 5
C05 = 160, t05 = 0 Pause the program and wait for operator's command
C06 = 100, t06 = 181 Deactivate AL1 relay and jump back to step 1

9:01 How to check current step information
9:13 Whay safety start feature does not work
11:24 How to manually jump the programming step

PID in this video: SYL-2352P http://bit.ly/2nqosN3

Another tutorial video by PMC Supplies: https://youtu.be/gHxoEomqEIo?t=32

Видео Ramp & Soak PID Programming Tutorial, Auber SYL-23X2P Series канала Auber Instruments Official