COOLING TOWER PERFORMANCE || How to check cooling tower performance in 10 minutes ||

Hello friends,

"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.

Calculation of Range, Approach & Effectiveness of Cooling Tower :-https://youtu.be/AApUhcqHOAE

Calculation of Make-up Water requirement of Cooling Tower :-https://youtu.be/EG-dUCzRhOI

Calculation of Cycle of Concentration [COC] :-https://youtu.be/LMXGfzrlMm0

Calculation of Heat Load of cooling tower :-https://youtu.be/ZnzLNitfOvc

Dry Bulb and Wet Bulb Temperature :-https://youtu.be/6ZFvZ0kdvNg

Losses in Cooling Tower :-https://youtu.be/CQkjiS8JriU

Email

powerplantdiscussion@gmail.com

Website

https://www.youtube.com/channel/UCyrySpYVNOxtjABxvGZXarA (Company Website)

LinkedIn

https://www.linkedin.com/in/power-plant-discussion-17a66219a

#PowerPlantDiscussion
#CoolingTowerPerformance

Thanks to all of you for connecting me.

Видео COOLING TOWER PERFORMANCE || How to check cooling tower performance in 10 minutes || канала Power Plant Discussion
Показать
Комментарии отсутствуют
Введите заголовок:

Введите адрес ссылки:

Введите адрес видео с YouTube:

Зарегистрируйтесь или войдите с
Информация о видео
18 февраля 2021 г. 17:43:38
00:13:32
Другие видео канала
Refrigeration Cycle Tutorial: Step by Step, Detailed and Concise!Refrigeration Cycle Tutorial: Step by Step, Detailed and Concise!Types of cooling towersTypes of cooling towersDRY BULB and WET BULB TEMPERATURE || DEW POINT TEMPERATURE || EVAPORATION COOLING ||DRY BULB and WET BULB TEMPERATURE || DEW POINT TEMPERATURE || EVAPORATION COOLING ||COC | Cycle of Concentration | Why we maintain COC of Cooling Tower?COC | Cycle of Concentration | Why we maintain COC of Cooling Tower?COOLING WATER PARAMETER || Conductivity, pH, Alkalinity, COC, LSI, Hardness, Chloride, FRC of CW ||COOLING WATER PARAMETER || Conductivity, pH, Alkalinity, COC, LSI, Hardness, Chloride, FRC of CW ||ORP || OXIDATION REDUCTION POTENTIAL || Why ORP maintain in Cooling tower and Drinking Water ||ORP || OXIDATION REDUCTION POTENTIAL || Why ORP maintain in Cooling tower and Drinking Water ||Cooling Tower || Induced draft cooling Tower || forced draft cooling Tower ||Cooling Tower || Induced draft cooling Tower || forced draft cooling Tower ||CEP [Condensate Extraction Pump] में Vacuum Balancing Line क्यों लगाते हैं? हिंदी में समझें!!CEP [Condensate Extraction Pump] में Vacuum Balancing Line क्यों लगाते हैं? हिंदी में समझें!!which chemical use in cooling tower 🤔⁉️cooling tower me konsa chemical padta hai.🤔PH.TDS.PPMwhich chemical use in cooling tower 🤔⁉️cooling tower me konsa chemical padta hai.🤔PH.TDS.PPMDIFFERENTIAL EXPANSION OF TURBINE || THERMAL EXPANSION OF TURBINE ||DIFFERENTIAL EXPANSION OF TURBINE || THERMAL EXPANSION OF TURBINE ||Cooling Tower InterviewCooling Tower InterviewHEAT LOAD OF COOLING TOWER || CAPACITY OF COOLING TOWER IN TR || TONNE OF REFRIGERANT ||HEAT LOAD OF COOLING TOWER || CAPACITY OF COOLING TOWER IN TR || TONNE OF REFRIGERANT ||DEAERATOR || WORKING & PRINCIPLES OF DEAERATOR || In HindiDEAERATOR || WORKING & PRINCIPLES OF DEAERATOR || In HindiCOOLING TOWER WATER TREATMENT || CORROSION INHIBITOR || DISPERSANT || BIOCIDE || SCALE INHIBITOR ||COOLING TOWER WATER TREATMENT || CORROSION INHIBITOR || DISPERSANT || BIOCIDE || SCALE INHIBITOR ||ACID TREATMENT || SULPHURIC ACID TREATMENT || WHY SULPHURIC ACID DOSE IN COOLING WATER || H2SO4 ||ACID TREATMENT || SULPHURIC ACID TREATMENT || WHY SULPHURIC ACID DOSE IN COOLING WATER || H2SO4 ||Centrifugal Pump Flow Rate Calculation | Cooling Tower Pump Flow Rate CalculationCentrifugal Pump Flow Rate Calculation | Cooling Tower Pump Flow Rate CalculationCHLORINATION || Purpose of Chlorination || FRC || Chlorine Demand || Effect of pH on Chlorination ||CHLORINATION || Purpose of Chlorination || FRC || Chlorine Demand || Effect of pH on Chlorination ||Steam flow rate required in Deaerator || why in Deaerator at above 100°C present in water form ||Steam flow rate required in Deaerator || why in Deaerator at above 100°C present in water form ||Feed Arrangements in MEE Plant | Parallel/Forward/Backward/Mixed feed arrangement in MEE Plant |Feed Arrangements in MEE Plant | Parallel/Forward/Backward/Mixed feed arrangement in MEE Plant |
Яндекс.Метрика