Загрузка страницы

CHLORINATION || Purpose of Chlorination || FRC || Chlorine Demand || Effect of pH on Chlorination ||

Hello friends,

"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.

Cooling Tower Water Treatment :-
https://youtu.be/OXW7E8MTgNc

Email

powerplantdiscussion@gmail.com

Website

https://www.youtube.com/channel/UCyrySpYVNOxtjABxvGZXarA (Company Website)

LinkedIn

https://www.linkedin.com/in/power-plant-discussion-17a66219a

#PowerPlantDiscussion
#Chlorination

Thanks to all of you for connecting me.

Видео CHLORINATION || Purpose of Chlorination || FRC || Chlorine Demand || Effect of pH on Chlorination || канала Power Plant Discussion
Показать
Комментарии отсутствуют
Введите заголовок:

Введите адрес ссылки:

Введите адрес видео с YouTube:

Зарегистрируйтесь или войдите с
Информация о видео
25 февраля 2021 г. 17:31:50
00:20:18
Другие видео канала
COOLING TOWER WATER TREATMENT || CORROSION INHIBITOR || DISPERSANT || BIOCIDE || SCALE INHIBITOR ||COOLING TOWER WATER TREATMENT || CORROSION INHIBITOR || DISPERSANT || BIOCIDE || SCALE INHIBITOR ||Why Exhaust Hood Temperature Increase During Turbine Rolling? What is Churning Effect in Turbine?Why Exhaust Hood Temperature Increase During Turbine Rolling? What is Churning Effect in Turbine?COOLING WATER PARAMETER || Conductivity, pH, Alkalinity, COC, LSI, Hardness, Chloride, FRC of CW ||COOLING WATER PARAMETER || Conductivity, pH, Alkalinity, COC, LSI, Hardness, Chloride, FRC of CW ||What is NPSH? || Purpose Of NET POSITIVE SUCTION HEAD maintained in Centrifugal Pump || [हिंदी]What is NPSH? || Purpose Of NET POSITIVE SUCTION HEAD maintained in Centrifugal Pump || [हिंदी]AXIAL DISPLACEMENT OF TURBINE || Methods for Controlling Axial Displacement of Turbine ||AXIAL DISPLACEMENT OF TURBINE || Methods for Controlling Axial Displacement of Turbine ||Cooling Tower || Induced draft cooling Tower || forced draft cooling Tower ||Cooling Tower || Induced draft cooling Tower || forced draft cooling Tower ||CEP [Condensate Extraction Pump] में Vacuum Balancing Line क्यों लगाते हैं? हिंदी में समझें!!CEP [Condensate Extraction Pump] में Vacuum Balancing Line क्यों लगाते हैं? हिंदी में समझें!!SPRING LOADED SAFETY VALVE OPERATION || PRESSURE & BLOWDOWN SETTINGS OF IT || [हिंदी]SPRING LOADED SAFETY VALVE OPERATION || PRESSURE & BLOWDOWN SETTINGS OF IT || [हिंदी]NATURAL DRAFT COOLING TOWER || Types of Cooling Tower || Cooling Tower || [हिंदी]NATURAL DRAFT COOLING TOWER || Types of Cooling Tower || Cooling Tower || [हिंदी]GLAND SEALING SYSTEM || SELF SEALING IN TURBINE || INTERSTAGE SEALING || [हिंदी]GLAND SEALING SYSTEM || SELF SEALING IN TURBINE || INTERSTAGE SEALING || [हिंदी]WOODWARD 505 GOVERNOR || KEY FUNCTION OF WOODWARD 505E GOVERNOR || [हिंदी]WOODWARD 505 GOVERNOR || KEY FUNCTION OF WOODWARD 505E GOVERNOR || [हिंदी]DM WATER//BOILER OPERATION ENGINEER//DEMINERALISED WATER// DM WATER USED IN POWER PLANT//BOE//ION EXDM WATER//BOILER OPERATION ENGINEER//DEMINERALISED WATER// DM WATER USED IN POWER PLANT//BOE//ION EXWHEEL CHAMBER PRESSURE IN STEAM TURBINE || Purpose of Wheel Chamber Pressure Monitor ||WHEEL CHAMBER PRESSURE IN STEAM TURBINE || Purpose of Wheel Chamber Pressure Monitor ||TURBINE DCS MONITORING || PARAMETER SHOULD BE MAINTAINED DURING NORMAL OPERATION OF TURBINE ||TURBINE DCS MONITORING || PARAMETER SHOULD BE MAINTAINED DURING NORMAL OPERATION OF TURBINE ||ACID TREATMENT || SULPHURIC ACID TREATMENT || WHY SULPHURIC ACID DOSE IN COOLING WATER || H2SO4 ||ACID TREATMENT || SULPHURIC ACID TREATMENT || WHY SULPHURIC ACID DOSE IN COOLING WATER || H2SO4 ||HP DOSING || PHOSPHATE TREATMENT || PHOSPHATE HIDE-OUT || In HINDIHP DOSING || PHOSPHATE TREATMENT || PHOSPHATE HIDE-OUT || In HINDIELECTROHYDRAULIC GOVERNOR || FUNCTION OF WOODWARD 505 GOVERNOR || [हिंदी]ELECTROHYDRAULIC GOVERNOR || FUNCTION OF WOODWARD 505 GOVERNOR || [हिंदी]ACID DUE POINT TEMPERATURE || WHY ESP CHARGE AT ABOVE 120°C || [हिंदी]ACID DUE POINT TEMPERATURE || WHY ESP CHARGE AT ABOVE 120°C || [हिंदी]LANGELIER SATURATION INDEX || LSI || Calculation of LSI || Effect of LSI on Positive and Negative ||LANGELIER SATURATION INDEX || LSI || Calculation of LSI || Effect of LSI on Positive and Negative ||Why Vacuum Is Created In the Condenser?Why Vacuum Is Created In the Condenser?
Яндекс.Метрика