Trane Gas Furnace No Heat - Testo 320 Uncovered Cracked Heat Exchanger & Bonus Toilet Repair
It's been awhile since I posted a furnace video - we don't have any warm air systems here. Majority of systems are hydronic or steam.
Pilot was out. Relight was good.
Checked combustion with the Testo 320 - similar to this one https://amzn.to/3kARV3B
Found 2 of the 3 heat exchanger tubes with a crack, which we proved by using the Testo 320 combustion analyzer.
Finished up the service call with a simple toilet repair.
Видео Trane Gas Furnace No Heat - Testo 320 Uncovered Cracked Heat Exchanger & Bonus Toilet Repair канала Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Pilot was out. Relight was good.
Checked combustion with the Testo 320 - similar to this one https://amzn.to/3kARV3B
Found 2 of the 3 heat exchanger tubes with a crack, which we proved by using the Testo 320 combustion analyzer.
Finished up the service call with a simple toilet repair.
Видео Trane Gas Furnace No Heat - Testo 320 Uncovered Cracked Heat Exchanger & Bonus Toilet Repair канала Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Показать
Комментарии отсутствуют
Информация о видео
2 марта 2021 г. 3:00:08
00:20:16
Другие видео канала
Heat Doesn’t Get Above 64 Degrees When It's Below 30 Outside - Discussing Options for Orthodox JewsWhat should you be looking at when doing a combustion analysis? (The basics!)Using Testo 320 Combustion Analyzer to Test For Proper Flue Gases If You Ain’t Checking Your GuessinWatching A Furnace Run With A Cracked Heat ExchangerReplacing A Cracked Heat ExchangerPLUMBING SHOWER DRAIN LEAKING DOWN INTO BASEMENT REPAIREDTriangle Tube Indirect Water Heater - Tank Failure Boiler Relief Flooding Boiler RoomFurnace Carbon Monoxide TestHow to use a combustion analysis meterSimple Furnace Heat Exchanger Test | Lennox Learning SolutionsTrane Heat Exchanger Replacement Start to Finishcalled to check gas furnace heat exchanger ,second opinionHacked AC Condenser Replacement - Compressors Failed Defective TVX & Daniel Gets a Torch HaircutGoodman Hole In Heat Exchangertesto 320 basic info to get startedUnit Heater Repair with the Testo 300combustion test gas furnace and water heatersFurnace Is Not Safe - Combustion Analysis - Is the Heat exchanger cracked?Navien NCB-240 Committing Suicide Combustion Gases Leaking