Kerdi-Coll 14 Day Flood Test - NOT WHAT I THOUGHT!
A follow up video to the Kerdi-Coll video I recently did : https://youtu.be/g85izsD6T5c
While it performed immensely better than without kerdi-coll, I was surprised to see any water migration at all.
I am not sure if water vapor has anything to do with the moisture, or if I should have done 2 coats instead of one (per ardex 8+9 Instructions). Not sure how a waterproof rubber membrane can let any moisture pass. But I know that water vapor can pass through stuff that water droplets can't. The way I understand it is: If a cooler surface (the side of the membrane with the water in it) meets a warmer air surface (the side of the mock up without water in it), water vapor molecules will be drawn through to the other side. Probably some kind of physics involved, which is way over my pay grade. I know that certain membranes are rated for steam showers, and some are not. I believe Laticrete Hydroban is not rated for steam showers because it allows to high of a vapor transmission rate. I doubt Ardex 8+9 would met steam shower vapor requirements either.
Anyways, hope you like the video.
Видео Kerdi-Coll 14 Day Flood Test - NOT WHAT I THOUGHT! канала TileCoach
While it performed immensely better than without kerdi-coll, I was surprised to see any water migration at all.
I am not sure if water vapor has anything to do with the moisture, or if I should have done 2 coats instead of one (per ardex 8+9 Instructions). Not sure how a waterproof rubber membrane can let any moisture pass. But I know that water vapor can pass through stuff that water droplets can't. The way I understand it is: If a cooler surface (the side of the membrane with the water in it) meets a warmer air surface (the side of the mock up without water in it), water vapor molecules will be drawn through to the other side. Probably some kind of physics involved, which is way over my pay grade. I know that certain membranes are rated for steam showers, and some are not. I believe Laticrete Hydroban is not rated for steam showers because it allows to high of a vapor transmission rate. I doubt Ardex 8+9 would met steam shower vapor requirements either.
Anyways, hope you like the video.
Видео Kerdi-Coll 14 Day Flood Test - NOT WHAT I THOUGHT! канала TileCoach
Показать
Комментарии отсутствуют
Информация о видео
Другие видео канала
Laticrete Hydro Ban Cementitious OUTPERFORMS Ardex 8+9 in Glass Box TestFLOOD TEST! RedGard SPEEDCOATHEATED FLOOR IN SHOWER!!! - How To Install SCHLUTER DITRA-HEATThis Schluter Kerdi Shower FAILED!!!- But Who's to BLAME???What Does SAL DIBLASI think of My KERDI TESTS???WHICH GROUT IS BEST??? Grout Testing with SHOCKING Results!!!Kerdi Fails 7 Day Sprinkler Test-- Sprinkler Test Part 3Rebuilding Failed Shower --- Installing Drain for Tile and WaterproofingWATERPROOF ADHESIVE INSTEAD OF THINSET FOR KERDI???-- Using Ardex 8+9 to Install KerdiWHAT is KERDI-COLL-L??? and WHY are THEY HIDING it from US?WORST TILE JOB I'VE SEEN - Can We Save It?THE BEST REDGARD VIDEO ON THE INTERNET!!!Why I Stopped Using Ardex 8+9TILE A SHOWER WALL---TUTORIALSPECTRALOCK 1 GROUT (TESTING) - IS IT WORTH IT?Massive WEDI Shower FAILURE (Done by Certified Installer) -- Warranty Claim DENIEDWALL FLOAT WITH NO LATH???--- Laticrete 3701 LITE Demonstration and Review!!!Are Pro Tile Installers ABANDONING Schluter Systems?Schluter Kerdi 7 Day Flood Test Results-- All Tile Guys Must See!!How to Install Schluter®-KERDI-LINE linear drain