EXCESS AIR || CALCULATION OF EXCESS AIR FROM O2% || [हिंदी]
Hello friends,
"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
Email
powerplantdiscussion@gmail.com
Website
https://www.youtube.com/channel/UCyrySpYVNOxtjABxvGZXarA (Company Website)
LinkedIn
https://www.linkedin.com/in/power-plant-discussion-17a66219a
#powerplantdiscussion
#excessair
#boeexam
Thanks to all of you for connecting me.
Видео EXCESS AIR || CALCULATION OF EXCESS AIR FROM O2% || [हिंदी] канала Power Plant Discussion
"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
powerplantdiscussion@gmail.com
Website
https://www.youtube.com/channel/UCyrySpYVNOxtjABxvGZXarA (Company Website)
https://www.linkedin.com/in/power-plant-discussion-17a66219a
#powerplantdiscussion
#excessair
#boeexam
Thanks to all of you for connecting me.
Видео EXCESS AIR || CALCULATION OF EXCESS AIR FROM O2% || [हिंदी] канала Power Plant Discussion
Показать
Комментарии отсутствуют
Информация о видео
Другие видео канала
![THEORETICAL/STOICHIOMETRIC AIR || FORMULA & CALCULATION || BOE EXAM PREPARATION || [हिंदी]](https://i.ytimg.com/vi/3tw3qYvOUZ4/default.jpg)
![O2 Analyser installed between Economiser and Air Preheater flue Gas duct why? || Hindi](https://i.ytimg.com/vi/RqrQYobQnsI/default.jpg)
![CEP [Condensate Extraction Pump] में Vacuum Balancing Line क्यों लगाते हैं? हिंदी में समझें!!](https://i.ytimg.com/vi/S_LEuA9Ov0w/default.jpg)
![AXIAL DISPLACEMENT OF TURBINE || Methods for Controlling Axial Displacement of Turbine ||](https://i.ytimg.com/vi/FpVkRdCGV9g/default.jpg)
![SPRING LOADED SAFETY VALVE OPERATION || PRESSURE & BLOWDOWN SETTINGS OF IT || [हिंदी]](https://i.ytimg.com/vi/38c-fUxPPzY/default.jpg)
![ENTHALPY और ENTROPY क्या होता है हिंदी में समक्षे!](https://i.ytimg.com/vi/4sn8BmBIFUQ/default.jpg)
![AFBC BOILER INTERLOCK || SEQUENCE OF FAN START UP IN AFBC BOILER || HINDI](https://i.ytimg.com/vi/z9r-3ZThvJk/default.jpg)
![Specific Steam Consumption || Specific Fuel consumption || Turbine & Plant Heat Rate Calculation ||](https://i.ytimg.com/vi/YMUbJ9LBQYo/default.jpg)
![WHAT IS BOILER || Boiler According to IBR || TYPES OF BOILER || [हिंदी]](https://i.ytimg.com/vi/HX-OVrkeFyw/default.jpg)
![GOVERNOR FUNCTION DROOP || PURPOSE OF DROOP || ADVANTAGE & DISADVANTAGE OF DROOP || [हिंदी]](https://i.ytimg.com/vi/F-IbGKJObyE/default.jpg)
![ACID DUE POINT TEMPERATURE || WHY ESP CHARGE AT ABOVE 120°C || [हिंदी]](https://i.ytimg.com/vi/RoGmUNedy1I/default.jpg)
![OIL LUBRICATION SYSTEM || FUNCTION OF JOP || AOP || MOP || EOP || FUNCTION OF OVERHEAD TANK [हिंदी]](https://i.ytimg.com/vi/aaB0T9k-UN8/default.jpg)
![Cooling Tower Calculation || Range, Approach, Efficiency and Effectiveness of cooling tower ||](https://i.ytimg.com/vi/AApUhcqHOAE/default.jpg)
![CFBC BOILER || LIGHT-UP PROCEDURES OF CFBC BOILER || In HINDI](https://i.ytimg.com/vi/_-Ndar0qrgE/default.jpg)
![GOVERNING OIL SYSTEM || WORKING PRINCIPLES OF GOVERNING OIL SYSTEM || [हिंदी]](https://i.ytimg.com/vi/nHw9EDOQqwo/default.jpg)
![CALCULATION OF EXCESS AIR BY CO2% || BOE Exam Preparation || [हिंदी]](https://i.ytimg.com/vi/y9wfQYVfbaY/default.jpg)
![PRIMING, FOAMING, CARRYOVER || Cause, Effects, Precautions, of it || In Hindi](https://i.ytimg.com/vi/QSQqII27B9M/default.jpg)
![SENSIBLE HEAT और LATENT HEAT क्या होता है हिंदी में समझे!](https://i.ytimg.com/vi/kZtgKP5Utjc/default.jpg)
![ACTUAL AIR SUPPLIED FOR COMBUSTION OF FUEL || MASS OF DRY FLUE GAS IN 1kg COAL || [हिंदी]](https://i.ytimg.com/vi/JS6ww4uO4zI/default.jpg)
![Oxygen analyser. Why Oxygen analyser installed between economizer and airpreheater ?](https://i.ytimg.com/vi/sIcqpC5GHDo/default.jpg)