Driver Operated 12W Led Chip Faulty #ledbulb
Checking a 12W Driver-Operated LED Chip with Multiple Burnt-Out SMD LEDs Using a Multimeter
When a 12W LED chip (SMD-based) stops functioning or shows signs of multiple SMDs being burnt out, it’s essential to diagnose the fault before replacing or repairing. Here’s how to perform a systematic check using a digital multimeter:
⸻
🔍 Tools Required:
• Digital Multimeter with Diode Test Mode
• Optional: Variable DC power supply (for advanced testing)
⸻
⚙️ Procedure:
1. Safety First
• Disconnect the LED chip from the AC mains.
• Discharge any capacitors in the driver circuit to avoid shock.
2. Visual Inspection
• Look for burn marks, darkened SMD LEDs, or cracked/bulged components.
• Burnt-out LEDs often appear darker or have a visible internal break.
3. Test SMD LEDs with Multimeter (Diode Mode)
• Set your multimeter to Diode Test Mode.
• Place the red probe on the anode (+) and black probe on the cathode (–) of each SMD LED.
Interpretation:
• A healthy LED will typically show a forward voltage drop (e.g., 1.8V to 3.2V, depending on LED type).
• An open circuit (no reading or OL) indicates a burnt
#ledsmd #ledbulb #diy #shortsfeed #shortsviral #troubleshooting
Видео Driver Operated 12W Led Chip Faulty #ledbulb канала Qureshi Store (Repairing)
When a 12W LED chip (SMD-based) stops functioning or shows signs of multiple SMDs being burnt out, it’s essential to diagnose the fault before replacing or repairing. Here’s how to perform a systematic check using a digital multimeter:
⸻
🔍 Tools Required:
• Digital Multimeter with Diode Test Mode
• Optional: Variable DC power supply (for advanced testing)
⸻
⚙️ Procedure:
1. Safety First
• Disconnect the LED chip from the AC mains.
• Discharge any capacitors in the driver circuit to avoid shock.
2. Visual Inspection
• Look for burn marks, darkened SMD LEDs, or cracked/bulged components.
• Burnt-out LEDs often appear darker or have a visible internal break.
3. Test SMD LEDs with Multimeter (Diode Mode)
• Set your multimeter to Diode Test Mode.
• Place the red probe on the anode (+) and black probe on the cathode (–) of each SMD LED.
Interpretation:
• A healthy LED will typically show a forward voltage drop (e.g., 1.8V to 3.2V, depending on LED type).
• An open circuit (no reading or OL) indicates a burnt
#ledsmd #ledbulb #diy #shortsfeed #shortsviral #troubleshooting