Vaillant Ecotec plus F54 F29 F28 part two for the eyes of gas engineer only.
10 Faults stored in the circuit board can be retrieved and in this case F54 F29 and F28 indicating unable to Standish ignition due to mainly gas or gas valve issue or the printed circuit board issue . It is important to carry out further tests as in video 2 to isolate if it is faulty gas valve or PCB
Select The power supply cables to the gas valve .
Select the two cables , each having two cables coloured blue and red.
The top one should get 22v dc at ignition when the gas valve is powered by the pcb while sparking.
The bottom one should change the dc voltage from 22 volts to between 12 to 16 vdc ( 12, 13 , 14, 15 or 16 )
If these tests are satisfactory then the PCB can be excluded from causing the fault.
Concentrate on the gas valve inlet side and notice the standing - static gas pressure and then check with manometer if the pressure drop is 4 Mbar at the ignition? If no drop , indicating gas valve is not opening and is at fault.
Видео Vaillant Ecotec plus F54 F29 F28 part two for the eyes of gas engineer only. канала unicuk
Select The power supply cables to the gas valve .
Select the two cables , each having two cables coloured blue and red.
The top one should get 22v dc at ignition when the gas valve is powered by the pcb while sparking.
The bottom one should change the dc voltage from 22 volts to between 12 to 16 vdc ( 12, 13 , 14, 15 or 16 )
If these tests are satisfactory then the PCB can be excluded from causing the fault.
Concentrate on the gas valve inlet side and notice the standing - static gas pressure and then check with manometer if the pressure drop is 4 Mbar at the ignition? If no drop , indicating gas valve is not opening and is at fault.
Видео Vaillant Ecotec plus F54 F29 F28 part two for the eyes of gas engineer only. канала unicuk
Показать
Комментарии отсутствуют
Информация о видео
Другие видео канала
![How to replace Vaillant ecotec plus or Vaillant ecotec pro diverter valve or three way valve](https://i.ytimg.com/vi/x4Gy1SZQd7Y/default.jpg)
![How to top up and increase boiler water pressure Vaillant ecotec + 938 repressure tp 1.4 bar](https://i.ytimg.com/vi/LFrEgbMtrbg/default.jpg)
![Bad boiler design contest- Worcester Bosch Greenstar CDi](https://i.ytimg.com/vi/cKc72cMunUg/default.jpg)
![Worcester Bosch greenstar common water leak](https://i.ytimg.com/vi/50LAMR8ZIt4/default.jpg)
![How many boilers Vaillant can make? Before they fit a jubilee clip?](https://i.ytimg.com/vi/WX2iCd-hNpE/default.jpg)
![Vaillant Ecotec plus boiler F54 F29 F28 part one](https://i.ytimg.com/vi/jUVDjjqd9fo/default.jpg)
![Vaillant Ecotec boiler F75 Due to blocked inbuilt filter and sensor](https://i.ytimg.com/vi/Uz10XFnJeKs/default.jpg)
![Lights not working semi enclosed fuse blown](https://i.ytimg.com/vi/dwOFwV_VooM/default.jpg)
![Boiler pump problems - Very loud when changing the speed](https://i.ytimg.com/vi/zyjZO3ilrV4/default.jpg)
![Baxi Combi boiler problems - loud Fan and boiler not igniting - faulty part found](https://i.ytimg.com/vi/V9TvDGCyIfk/default.jpg)
![Keston C40 problems Loud sound with vibraton](https://i.ytimg.com/vi/aTuIjLymGi8/default.jpg)
![Vaillant boiler problems - Scaled heat exchanger inside combustion chamber](https://i.ytimg.com/vi/S2e84fH9MSA/default.jpg)
![Vaillnat boiler problems F28 part 2](https://i.ytimg.com/vi/JpsI1SOkBzc/default.jpg)
![Worcester bosch boiler problems - was not not igniting - working after repair](https://i.ytimg.com/vi/yP07hv8Cl1g/default.jpg)
![Worcester bosch boiler problems Fan on but not igniting](https://i.ytimg.com/vi/Yo56T2LDsJs/default.jpg)
![noisy Potterton Suprima 80 L Defective part Two](https://i.ytimg.com/vi/3rw8-amK1HE/default.jpg)
![noisy Potterton Suprima 80 L Defective part one](https://i.ytimg.com/vi/oTXMcQw3vsQ/default.jpg)
![Potterton Suprima flasing red light 2 per sec lockout](https://i.ytimg.com/vi/al3ly0-9b0I/default.jpg)
![Ariston micro genus 2 24MFFI boiler not firing at all -](https://i.ytimg.com/vi/DI8qCybgOzE/default.jpg)
![Brand New Heatline Capriz plus boiler pump noisy - Heatline repair London](https://i.ytimg.com/vi/1giQmUj_Nx4/default.jpg)