Загрузка страницы

SOOT JOB Sweeping wood gasification boiler before winter

Every now and then exhaust gas temperature goes sky high and it's time for a SOOT JOB.

Lets see how this is done with Atmos gasifigation boiler!

ATMOS DC50 boiler is equipped with a special chamber which is on both sides laid with special ceramic shaped parts, with primary air inlets in the lower section and with ceramic nozzle and in lower chamber with spherical ceramic parts. Rear flue duct is equipped with a tubular heat exchanger.

Gasification of wood (inverse burning) with subsequent combustion of wood gas in ceramic combustion chamber ensures optimum burning of all combustible components. The air supply and combustion process are controlled with exhaust fan. This allows quick ignition and good combustion of the boiler since the firing up. The flame temperature is 1000 - 1250 ° C.

Inverse burning (gasification) and ceramic combustion chamber enable practically complete combustion with a minimum of harmful exhalations.

0:00 Soot job introduction
1:50 Dropping ashes from warehouse chamber
2:30 Using MAGNET for the NAILS & STUFF to separate those away from the ashes
3:26 Sweeping & cleaning ceramic fire chamber
4:36 Cleaning TURBULATORS & HEAT RECOVERY TUBES
9:10 Removing boiler backside ash & smoke duct inlet COVERS
12:13 Removing ash below heat recovery tubes
13:43 SMOKE DUCT ASH TRAP cleaning
17:28 FIRING UP the boiler
22:25 RECYCLING ASH (=NUTRIENTS) back into the forest
25:58 DAD JOKE (=facepalm) & THANK YOU for watching!!!
26:45 Topping up boiler & FINALIZING CLEANING THINGS

Видео SOOT JOB Sweeping wood gasification boiler before winter канала Juha Erkkila