AC fixed. Bad dryer. Not compressor. No leaks. Clogged high pressure lines from dryer debris.

After doing a vacuum test and not having a leak, then recharging it and having the high pressure line pressuring, yet the low side didn't change. It pressurised but never went down. That's when I knew it was plugged on the low side @ the expansion valve. I couldn't clear the lines, so I just replaced them, from the dryer to the expansion valve. The consessent from the dryer plugged the line. My dryer went bad, opening internally. Nothing went into the evaporator. I checked. So from the dryer to the expansion valve had the problem and particles. I bought the vacuum kit online for $120.00. Ebay. Vacuumed it and recharged it with Freon/oil the amount stated on the firewall. After everything it costed under 1000. I bought a compressor and dryer, still had the problem. It was semi cold at an idle. But when driving, it got hot. After reading both high side and low side from my ordered kit(gauges with pump), it was clear the low side had the problem. I hope this helps others figure out a possible problem.