F13 Fault Code - Fan Speed Error
HTP: Fault Code F13: FAN SPEED ERROR: The fan is not running at the speed that the control has commanded it to run at. The fan speed had been more than 30% faster or slower than the commanded speed for more than 10 seconds. The red light will display and the word LOCKOUT will flash. This code indicates a serious safety issue and the boiler will not restart until the cause is determined by a technician and he pushes the RESET button on the display. During this lockout fault, the pump will be on as indicated on the second line.
1. Check the combustion air fan wiring.
2. Measure the DC voltage from the red fan wire to ground while it is connected to the fan. It should be between 24 to 40 volts. If it is lower than 24 volts, check for excessive external loads connected to the boiler sensor terminals. Disconnect the 5 pin plug from the fan and check the voltage on the red wire again. If it is now between 24-40 volts, replace the fan. If it is still below 24 volts replace the boiler control board.
Видео F13 Fault Code - Fan Speed Error канала HTP Comfort Solutions LLC.
1. Check the combustion air fan wiring.
2. Measure the DC voltage from the red fan wire to ground while it is connected to the fan. It should be between 24 to 40 volts. If it is lower than 24 volts, check for excessive external loads connected to the boiler sensor terminals. Disconnect the 5 pin plug from the fan and check the voltage on the red wire again. If it is now between 24-40 volts, replace the fan. If it is still below 24 volts replace the boiler control board.
Видео F13 Fault Code - Fan Speed Error канала HTP Comfort Solutions LLC.
Показать
Комментарии отсутствуют
Информация о видео
15 июля 2016 г. 22:28:34
00:03:03
Другие видео канала
ER: 40 - Gas Leakage is Detected on EFT Combination BoilerER40 - Gas Leakage on Hydra Smart RT Tankless Water HeaterQuick Zone Manifold SystemHTP Heavy Duty Gas Water Heater Troubleshooting Step 3Elite XL Combustion & Gas Pressure TestingHTP's Phoenix Plus OverviewPhoenix Installation Training - Electronics2016 HTP SolarError Code 37 on the EFTC 140FCEO Dave Davis explains the Versa-Hydro, Part IHTP Part 1 -- AHR Expo 2008F00 Fault Code for Tanks -HTP Heavy Duty Gas Water Heater Troubleshooting Step 2Error code: ER35 - Hydra Smart Residential - HTP Tankless Water HeaterAir / Dirt Separator for the Pioneer and Versa-Flame BoilersPhoenix Light Duty Installation - IntroEFT COMBI Wall TrainingER: 28 - Overheat Sensor Open or ShortER 31 - Water Inlet Sensor ErrorHTP Mod Con Boiler Double Stack Overview -Error Code 70 on the EFTC 140F