Weil McLain Ultra 3 299k Alive After Neglected Annual Maintenance
Honestly, this one is boring. Just routine maintenance on a neglected Ultra boiler. But...Getting it done. This WM was neglected for several years. Look at how clogged up the HX is...
Cleaned her out. Washed her down. Good to go.
This is the tool: https://amzn.to/3otqnOS
or here:
https://www.supplyhouse.com/Weil-McLain-591-706-200-Heat-Exchanger-Cleaning-Tool-w-Handle?gclid=Cj0KCQiA6Or_BRC_ARIsAPzuer_OYHepBSwxxVpzevXnzJ2Onc-4DF802ZHZOhybyp7AVdRbWvXrqeQaApJ5EALw_wcB
The maintenance kit for the 299 is:
https://amzn.to/2XzLrat
Видео Weil McLain Ultra 3 299k Alive After Neglected Annual Maintenance канала Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Cleaned her out. Washed her down. Good to go.
This is the tool: https://amzn.to/3otqnOS
or here:
https://www.supplyhouse.com/Weil-McLain-591-706-200-Heat-Exchanger-Cleaning-Tool-w-Handle?gclid=Cj0KCQiA6Or_BRC_ARIsAPzuer_OYHepBSwxxVpzevXnzJ2Onc-4DF802ZHZOhybyp7AVdRbWvXrqeQaApJ5EALw_wcB
The maintenance kit for the 299 is:
https://amzn.to/2XzLrat
Видео Weil McLain Ultra 3 299k Alive After Neglected Annual Maintenance канала Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Показать
Комментарии отсутствуют
Информация о видео
9 января 2021 г. 8:26:18
00:23:06
Другие видео канала
New Yorker Boiler No Heat & Making Loud NoiseWeil McLain CGA6 Natural Gas Boiler Installationold weil mclain oil fired pancake boiler,check@cleanAnother Plumber “Didn’t Have Time” to fix their Burnham Steam Boiler with wires burnt & high COWhy This Navien CH-240 Didn’t Explode Yet? & Sorry Sir: “You don’t need a new boiler” Honest PlumberFriend Who Knows HVAC Just Replaced The TXV & Now All The Freon Is Gone! Oh, & He Works on Big UnitsCentral AC Frozen Again & Making Loud Noise - Using MeasureQuick & HVAC School Capacitor CalculatorTypical Day of an HVAC Owner & Technician - Multiple Service Calls ResolvedElderly Senior Citizen Woman Gets Ripped Off - Condensate Drain Clogged & Pulled 10 Year Old FilterIBC CONDENSING BOILER NEUTRALIZER AND LIFT PUMP ADDEDDouble Feature! 1st Call We Walked Away & 2nd Replaced 7 loop Uponor Radiant Manifold w/ActuatorsYou Paid How Much for this Central AC Installation? OMG! Another Hack Job Discovered - Ripped Off!gas boiler serviceDead ECM Blower Motor in Goodman Air Handler Replaced with Traditional 1/2 HP 1075 RPM Blower MotorPrevented Boiler From Exploding! Navien NCB-240E 2 Zone From CH-240 with 150psi Relief Valve & LeaksHow to use a tubing bender on 1/2” L Copper Tubing - Installation of a Burnham Gas Steam BoilerWater Heater Back Drafting & Flame Roll Out with Several Code Violations - Owner Won't ListenConfused Gas Heat System! Either No Heat or Overheats! Bad Circulator & Check Valve - Problem SolvedHow To Perform Annual Maintenance Navien NCB-180E & Let's Fight ESRD Kidney Failure Watch & Listen