Загрузка страницы

Cum intram in meniul secret(diagnoza) Climatronic la VW Golf 4 / Passat b5 / Jetta / Polo / Bora

Cum intram in meniul secret(diagnoza) climatronic la VW Golf 4 / Passat b5 / Jetta / Polo / Bora

Toate functiile :
1 Digital value of Interior Temperature Sensor, in Headliner (G 86
2 Digital value of Interior Temperature Sensor, in Instrument Panel (G 56)
3 Digital value of Fresh Air Intake Duct Temperature Sensor (G 89)
4 Digital value of Outside Air (Ambient) Temperature Sensor (G 17), front
5 Digital value of Outside Air (Ambient) Temperature Sensor
6 Digital value of Ambient Temperature Sensor At Fresh Air Blower (G 109)
7 Digital value of Temperature Regulator Flap Motor Potentiometer (G 92)
8 Delta value of Temperature Regulator Flap
9 Non-corrected specified value of Temperature Regulator Flap
10 Digital value of Central Flap Motor Potentiometer (G 112)
11 Specified value of Central Flap
12 Digital value of Footwell/Defroster Flap Motor Potentiometer (G 114)
13 Specified value of Footwell/Defroster Flap
14 Digital value of Air Flow Flap Motor Potentiometer (G 113)
15 Specified value of Air Flow Flap
16 Vehicle Speed (km/h)
17 Actual Air Blower voltage (Volts)
18 Specified Fresh Air Blower voltage (Volts)
19 A/C Compressor (A/C Clutch) voltage (Volts)
20 Number of low voltage occurrences, non-transient
21 Cycle condition of A/C Refrigerant High Pressure Switch (F 118)
22 Cyclings of the A/C Refrigerant High Pressure Switch (F 118)
23 Cyclings of the switches, absolute non-fluctuating
24 Analog/Digital value, Kick-Down Switch
25 Analog/Digital value, Engine Coolant Temperature (ECT) Warning Light
26 Engine Speed (RPM)
27 N/A
28 A/C Compressor speed in rpm (Equals Engine Speed x 1.28)
29 Software version
30 N/A
31 Potentiometer malfunction counter, Temperature Regulator Flap
32 Potentiometer malfunction counter, Central Flap
33 Potentiometer malfunction counter, Footwell/Defroster Flap
34 Potentiometer malfunction counter, Air Flow Map
35 Feedback value, cold end-stop, Temperature Regulator Flap Motor Potentiometer (G 92)
36 Feedback value, hot end-stop, Temperature Regulator Flap Motor Potentiometer (G 92), max. stop
37 Feedback value, cold end-stop, Central Flap Motor Potentiometer (G 112)
38 Feedback value, hot end-stop, Central Flap Motor Potentiometer (G 112)
39 Feedback value, cold end-stop, Footwell/Defroster Flap Motor Potentiometer (G114)
40 Feedback value, hot end-stop, Footwell/Defroster Flap Motor Potentiometer (G114)
41 Feedback value, cold end-stop, Air Flow Map Motor Potentiometer (G 113)
42 Feedback value, hot end-stop, Air Flow Map Motor Potentiometer (G 113)
43 Vehicle operation cycle counter
44 Calculated interior temperature (internal software, in digits)
45 Outside (ambient) temperature, filtered, for regulation (internal software)
46 Outside (ambient) temperature, unfiltered, (internal software, in deg C)
47 Outside (ambient) temperature, unfiltered, (in digits)
48 Malfunction counter for speedometer (vehicle speed) signal
49 Standing time (in minutes)
50 Engine Coolant Temperature (ECT) in deg C
51 Windshield Wiper Mode = Dig. (0=Off, 1 = Int, 2=On)
52 Fdk-Correction wrt Wiper Mode = Dig.
53 Blower Voltage Correction wrt Wiper Mode = 0.1V