Delany (Flushboy, Rex, Presto) Flushometer | Diaphragm | Repair and Replace
In this episode of Repair and Replace, Vance shows how to replace a diaphragm in a Delany Flushboy, Rex, or Presto flush valve. This applies to both commercial toilets (water closets) and urinals.
Note: these steps might be compatible with Crane / Powers flush valves as the models are very similar.
The bypass hole size is extremely important for proper metering of water. Continuous flushing can occur if the bypass hole is blocked. If the hole has been enlarged, it can cause short flushing.
Browse flushometer replacement parts: http://www.amresupply.com/catalog/674794
Browse Diaphragms: https://www.amresupply.com/catalog/Diaphragms-PF12
More Delany Flushboy, Rex, or Presto Repairs:
https://www.youtube.com/playlist?list=PLCo9SMjkdWBxiJUBfdBZxGy6n4OTrmbri
___________________________
00:00 Intro
00:22 What You'll Need
00:30 How it Works
01:37 Step 1: Shut Off the Water
01:56 Step 2: Remove the Diaphragm
02:29 Step 3: Replace the Diaphragm
03:15 Step 4: Install the Diaphragm
03:42 Step 5: Flush Volume Adjustments
___________________________
AMRE Supply provides homeowners, service contractors, and property management with the parts and knowledge needed to get the best performance out of any property. Stocking the largest selection of appliance parts, heating, plumbing, lighting, and janitorial supplies, AMRE ships almost anywhere in Canada within 24 - 48 hours. Expert help is available online, over the phone or in person at one of the many locations across Canada.
Connect with AMRE Supply
Website - https://www.amresupply.com
Facebook - https://www.facebook.com/amresupply
Twitter - https://twitter.com/amresupply
Instagram - https://www.instagram.com/amresupply
Видео Delany (Flushboy, Rex, Presto) Flushometer | Diaphragm | Repair and Replace канала AMRE Supply
Note: these steps might be compatible with Crane / Powers flush valves as the models are very similar.
The bypass hole size is extremely important for proper metering of water. Continuous flushing can occur if the bypass hole is blocked. If the hole has been enlarged, it can cause short flushing.
Browse flushometer replacement parts: http://www.amresupply.com/catalog/674794
Browse Diaphragms: https://www.amresupply.com/catalog/Diaphragms-PF12
More Delany Flushboy, Rex, or Presto Repairs:
https://www.youtube.com/playlist?list=PLCo9SMjkdWBxiJUBfdBZxGy6n4OTrmbri
___________________________
00:00 Intro
00:22 What You'll Need
00:30 How it Works
01:37 Step 1: Shut Off the Water
01:56 Step 2: Remove the Diaphragm
02:29 Step 3: Replace the Diaphragm
03:15 Step 4: Install the Diaphragm
03:42 Step 5: Flush Volume Adjustments
___________________________
AMRE Supply provides homeowners, service contractors, and property management with the parts and knowledge needed to get the best performance out of any property. Stocking the largest selection of appliance parts, heating, plumbing, lighting, and janitorial supplies, AMRE ships almost anywhere in Canada within 24 - 48 hours. Expert help is available online, over the phone or in person at one of the many locations across Canada.
Connect with AMRE Supply
Website - https://www.amresupply.com
Facebook - https://www.facebook.com/amresupply
Twitter - https://twitter.com/amresupply
Instagram - https://www.instagram.com/amresupply
Видео Delany (Flushboy, Rex, Presto) Flushometer | Diaphragm | Repair and Replace канала AMRE Supply
Показать
Комментарии отсутствуют
Информация о видео
Другие видео канала
Pro Tip - Floor Traffic Patterns | Clean CareCarrier Bryant # 332505-751 - Continuity Test (Gas Furnace Ignitor)Sump Pump Features | Spec. SenseTOTO EcoPower Flushometer (Pre-2013) | Sensor | Repair and ReplaceWhite Rodgers # 768A-844 - Continuity Test (Gas Furnace Ignitor)Whirlpool # WP8182528 - Continuity Test (Dryer Heating Element)Humidifier Drip Tray: Repair and Replace (White Rodgers HFT2100)How to Use Teflon Tape (Quick Guide) | Repair and ReplacePro Tip - Floor Finish Thickness | Clean CareGeneral Electric # WE25M27K - Continuity Test (Dryer Heating Element)Pro Tip - Water Temperature | Clean CareRobertshaw # 41-410 - Continuity Test (Gas Furnace Ignitor)Frigidaire # 5300622032 - Continuity Test (Dryer Heating Element)Pro Tip - Directing Water Flow | Clean CareRobertshaw # 41-413 - Continuity Test (Gas Furnace Ignitor)TOTO Manual Flushometer | Vacuum Breaker | Repair and ReplaceRefrigerator Compressor Starter - How it Works | Repair & ReplaceHumidifier Water Distributor: Repair and Replace (Air King AK7000)A Thank You to Our SubscribersHow Do Solenoids Work in Appliances? | Repair and ReplacePro Tip - Dish Soap | Clean Care