Compressor not building pressure? - Identifying issue and replacing top end kit (Valves & Gaskets)

Is your air compressor is running continuously but not building pressure? This can mean a few things.
1 – Air leaks? Isolate your air compressor and check that it can build pressure to the vessel in a timely manner
2 – Check your air intake filter as shown in video (Blockages or faulty intake filters will restrict)
3 – Check the internal valves and gaskets – a broken valve or gasket is more likely to be the issue if the above are fine.
This video will demonstrate on how to identify these issues. Always contact your manufacturer if this will void any warranties before disassembling your pump. The air compressor used in this video is a Peerless P14 fitted with a N75 industrial pump. This pump has a manufacturer warranty of 5 years. Depending on your air compressor (if a Peerless model) the valve and gaskets will vary, so be sure to check out the Peerless Products spare parts page to easily identify the right components https://www.peerlessproducts.com.au/spare-parts/.
The information provided in this video can be helpful on any type of piston air compressor.