Загрузка...

Basengreen 16kWh Battery(V3 BMS) | Victron Inverter Communication Video

In this video, we will explain the key points for victron inverter communication
1. Select Victron CAN protocol on battery
2. For communication cable, one side has to be crimped the RJ45 connector(PIN 7-CAN H, PIN 8-CAN L), plug it to the Cerbo GX BMS.CAN port, and plug the Victron RJ45 terminator to the near port, plug the other side to Battery CAN port
3. For single battery, make sure the dip address is 000000
4. For Cerbo GX, set up the CAN-bus BMS LV(500 kbit/s) on the CAN-bus profile
5. You will see 1 battery online shown on the Cerbo GX if the communication is successful

For more details, please visit: www.basenpower.com