Загрузка страницы

Goodman Condenser Replacement - (start to finish)

Replacing a 2.5 ton Goodman condensing unit. Refrigerant recovery. Removing the old condensing unit. Brazing in the new condenser. Installing the new condensing unit. Air conditioning evacuation. Adjusting refrigerant charge.
410a Refrigerant. Not a DIY video. EPA type 1 and 2 or Universal certification required in the United States.
00:00 - setting up tools for condenser replacement
00:30 - refrigerant recovery
01:12 - condenser removal
04:55 - new condenser installation
08:50 - ac system evacuation
14:05 - breaking vacuum
16:26 - opening new king valves
17:50 - starting up new condensing unit

HVAC tools I use to pull fast, deep vacuums.

Vacuum Hoses - https://amzn.to/3ytDi97

Vacuum Pump - https://amzn.to/3vgYay7
Evacuation Manifold - https://amzn.to/34oo2fX
Vacuum rated Valve Core Removal Tools - https://amzn.to/3yAHSCg

For condensing units

HVAC service wrench - https://amzn.to/3uhJQEe