First Post:
Any advice on this fault please. gas pressure is correct, burners are clear of obstructions, all seems correctly assembled...but the small solenoid about the regulator is turning on and allowing a big flame up...model PH SFSSH60W. Nat gas 1.0kpa
Follow Up Fix/Report:
Pitco Frialator SSH Series - Flame Up on Ignition, eventually it will trip the overtemp protection (Roll Out Switch), It seems the cause will be the small silver gas 'SCB' solenoid (Self Cleaning Burner). The solenoid seem to fail open or partly open at startup, causing an excess of unburnt gas to fill the SCB runner tube and on ignition there is a large flame around the burner area, its pretty scary if your not familiar with these types of faults...
First you should carry out normal checks like;
1. Check Gas Pressure (X.X kPA on nameplate) p14 in manual (link below)
2. Remove the burner components and check for any blockages in the burner heat tubes or baffles (eg. soot, broken parts, or maybe a small albatross) that may be causing poor flow thru the burner tubes and making it backup into the front component area.
3. I was able to contact Pitco Technical team and they helped me thru the process, suggesting possible blockage in the SCB system, leakages in the pilot flex tube assy, incorrect SCB orifice, possible electrical fault on the mainboard or relay failure, or the SCB solenoid maybe faulty.
At this point after checking all or the above and without spare parts to replace control board etc I tried lightly tapping the SCB solenoid with a "technical spanner", restarted the machine and its working fine now...but needs a new SCB solenoid - currently on order...
Thanks Pitco for your help direct from USA while late at night here is Australia!
https://www.youtube.com/watch?v=3Sm-JF04Xcg
https://www.manualslib.com/manual/1457544/Pitco-Sg-Series.html?term=theory&selected=1&page=7#manual
PS: I will add a Youtube link if the Fryer working correctly, when I go back to replace the SCB solenoid.
Hope this helps someone...GH
Видео Pitco Frialator - fault on ignition канала Rusty Trucks Australia - Graeme Holman
Any advice on this fault please. gas pressure is correct, burners are clear of obstructions, all seems correctly assembled...but the small solenoid about the regulator is turning on and allowing a big flame up...model PH SFSSH60W. Nat gas 1.0kpa
Follow Up Fix/Report:
Pitco Frialator SSH Series - Flame Up on Ignition, eventually it will trip the overtemp protection (Roll Out Switch), It seems the cause will be the small silver gas 'SCB' solenoid (Self Cleaning Burner). The solenoid seem to fail open or partly open at startup, causing an excess of unburnt gas to fill the SCB runner tube and on ignition there is a large flame around the burner area, its pretty scary if your not familiar with these types of faults...
First you should carry out normal checks like;
1. Check Gas Pressure (X.X kPA on nameplate) p14 in manual (link below)
2. Remove the burner components and check for any blockages in the burner heat tubes or baffles (eg. soot, broken parts, or maybe a small albatross) that may be causing poor flow thru the burner tubes and making it backup into the front component area.
3. I was able to contact Pitco Technical team and they helped me thru the process, suggesting possible blockage in the SCB system, leakages in the pilot flex tube assy, incorrect SCB orifice, possible electrical fault on the mainboard or relay failure, or the SCB solenoid maybe faulty.
At this point after checking all or the above and without spare parts to replace control board etc I tried lightly tapping the SCB solenoid with a "technical spanner", restarted the machine and its working fine now...but needs a new SCB solenoid - currently on order...
Thanks Pitco for your help direct from USA while late at night here is Australia!
https://www.youtube.com/watch?v=3Sm-JF04Xcg
https://www.manualslib.com/manual/1457544/Pitco-Sg-Series.html?term=theory&selected=1&page=7#manual
PS: I will add a Youtube link if the Fryer working correctly, when I go back to replace the SCB solenoid.
Hope this helps someone...GH
Видео Pitco Frialator - fault on ignition канала Rusty Trucks Australia - Graeme Holman
Показать
Комментарии отсутствуют
Информация о видео
2 декабря 2021 г. 16:15:46
00:00:15
Другие видео канала
1930 Racecar Build - recreating the 1936 KB Scripps Booth flathead 'V8 Special' (Teaser)Langkawi Wildlife 🐍Mako Visit Steep Point SharkBay May 2017Rescuing an early K5 Inter, plus we deliver & find our first Rusty Truck Pick - another K5 Inter...another picking trip, overnight camp. & wedding anniversary...Gliding around Mt Cook New Zealandquick delivery job to Yanchep today...Mercedes Vito W639 Manual Gearbox Selector RepairRescuing an Austin Truck https://www.facebook.com/groups/529855654639385/?ref=share_group_linkRusty Truck Adventures... (inc 1936 Chev Truck)delivering the 47' Bedford KM Tray. we meet new owner Dave, his friendly neighbour, and Dave's wife!Finding Water in Sand DunesTaffys Ferris Wheel - Ready for viewing! Koombana Bay, Bunbury.9 December 2023Mondeo Battery Drain FixCrabbing in Cowell, SA. 100 Crabs 3 hours. good times with mates...Fun Facts with Pappa G - Lightning strike..Estes Rocket DenverThe picking truck gets a headboard, winch base upgrade...ISRI Air Suspension Seat RepairX BULL Electric Winch Service