Dr Amp Ep2_Three Types of UPS System Technologies
What is a UPS -Uninterruptible Power Supply?
The purpose of a UPS is to provide emergency power (usually by a lead/acid battery) to a load when it senses that the input power source has failed. They are different from emergency power systems or standby generators because they provide near-instantaneous protection from power interruption by using a battery (which can be a supercapacitor or flywheel).
The battery itself usually has a short runtime (about 5-20 minutes), but it should be enough to either save all that precious data/progress that you have made, gracefully shut everything down, or fix the problem that caused the outage.
A UPS can be used to protect hardware like data centres, computers, and other electrical equipment where an unexpected surge/sag can cause serious problems like data loss, business disruption, and even injuries or fatalities.
Now Types of Uninterruptible Power Supplies
1. OFFLINE / STANDBY UPS.
The offline/standby UPS is the most basic out of the three. It provides light surge protection and battery back-up.
The key factor of this type of ups are
It is Inexpensive & Cost-effective choice for small and less critical & stand-alone application e.g. PC’s, Peripherals.
It is simple to use & hence reliable.
• Rides out more than 90% of mains outages.
• Overall effectiveness – 55%
• The critical load is supplied by mains in normal mode
• Inverter starts and supplies load during mains failure
• There is “10 – 15 millisecond. Power Break” during every mains failure and resumption.
2. LINE INTERACTIVE UPS
The line-interactive UPS has a similar design to the offline/standby, but with properties of an online/double-conversion as well.
The key factor of this type of ups are:
• Highly effective power conditioning and UPS backup system.
• Mostly suited for application areas where power outages are rare but there are frequent voltage fluctuations.
• Accepts a wide range of input voltage variation higher up to +15% to negative up to –25% Typ.)
• They have Higher energy efficiency and Overall effectiveness is about – 85%
• Single power converter does function of converting AC to DC and DC to AC.
• There is no load changeover relay on the output side and hence there is no break in output power to the load during the mains failure or resumption.
• Relay disconnects the UPS from mains during a mains failure condition.
3. ONLINE- UPS
The online/double-conversion UPS differs from the offline/standby as the DC/AC inverter is always connected on. This means there will be no transfer time between the main power source and battery, providing greater protection against spikes, sags, electrical noise, and complete power failure.
The key factor of this type of ups are:
• Provides the highest level of power protection and power conditioning and backup.
• Zero switchover time during mains outages.
• Completely Regenerated output power and not just conditioning of the mains power as in Off-line or Line-Interactive UPS.
• Provides frequency regulation (Essential for operation with backup D.G. sets)
• Overall effectiveness – 100%
To know more about our Services Call us at 9696086262 or email us at info@msplgroup.com
Also, you can visit our online website: www.mspwebstore.com
Follow us on FACEBOOK: https://www.facebook.com/mahavirsyspo...
LINKEDIN: https://www.linkedin.com/company/1453...
INSTAGRAM: https://www.instagram.com/mahavir_sys…
LICENSE CERTIFICATE: Envato Elements Item
=================================================
This license certificate documents a license to use the item listed below
on a non-exclusive, commercial, worldwide and revokable basis, for
one Single Use for this Registered Project.
Item Title: Corporate Music
Item URL: https://elements.envato.com/corporate-music-HZGUFM4
Item ID: HZGUFM4
Author Username: HimProduction
Licensee: Pranav Shah
Registered Project Name: MSP TV
License Date: November 20th, 2020
Item License Code: 9Y2V6MPWQL
The license you hold for this item is only valid if you complete your End
Product while your subscription is active. Then the license continues
for the life of the End Product (even if your subscription ends).
For any queries related to this document or license please contact
Envato Support via https://help.elements.envato.com/hc/en-us/requests/new
Envato Elements Pty Ltd (ABN 87 613 824 258)
PO Box 16122, Collins St West, VIC 8007, Australia
==== THIS IS NOT A TAX RECEIPT OR INVOICE ====
Видео Dr Amp Ep2_Three Types of UPS System Technologies канала MSP TV
The purpose of a UPS is to provide emergency power (usually by a lead/acid battery) to a load when it senses that the input power source has failed. They are different from emergency power systems or standby generators because they provide near-instantaneous protection from power interruption by using a battery (which can be a supercapacitor or flywheel).
The battery itself usually has a short runtime (about 5-20 minutes), but it should be enough to either save all that precious data/progress that you have made, gracefully shut everything down, or fix the problem that caused the outage.
A UPS can be used to protect hardware like data centres, computers, and other electrical equipment where an unexpected surge/sag can cause serious problems like data loss, business disruption, and even injuries or fatalities.
Now Types of Uninterruptible Power Supplies
1. OFFLINE / STANDBY UPS.
The offline/standby UPS is the most basic out of the three. It provides light surge protection and battery back-up.
The key factor of this type of ups are
It is Inexpensive & Cost-effective choice for small and less critical & stand-alone application e.g. PC’s, Peripherals.
It is simple to use & hence reliable.
• Rides out more than 90% of mains outages.
• Overall effectiveness – 55%
• The critical load is supplied by mains in normal mode
• Inverter starts and supplies load during mains failure
• There is “10 – 15 millisecond. Power Break” during every mains failure and resumption.
2. LINE INTERACTIVE UPS
The line-interactive UPS has a similar design to the offline/standby, but with properties of an online/double-conversion as well.
The key factor of this type of ups are:
• Highly effective power conditioning and UPS backup system.
• Mostly suited for application areas where power outages are rare but there are frequent voltage fluctuations.
• Accepts a wide range of input voltage variation higher up to +15% to negative up to –25% Typ.)
• They have Higher energy efficiency and Overall effectiveness is about – 85%
• Single power converter does function of converting AC to DC and DC to AC.
• There is no load changeover relay on the output side and hence there is no break in output power to the load during the mains failure or resumption.
• Relay disconnects the UPS from mains during a mains failure condition.
3. ONLINE- UPS
The online/double-conversion UPS differs from the offline/standby as the DC/AC inverter is always connected on. This means there will be no transfer time between the main power source and battery, providing greater protection against spikes, sags, electrical noise, and complete power failure.
The key factor of this type of ups are:
• Provides the highest level of power protection and power conditioning and backup.
• Zero switchover time during mains outages.
• Completely Regenerated output power and not just conditioning of the mains power as in Off-line or Line-Interactive UPS.
• Provides frequency regulation (Essential for operation with backup D.G. sets)
• Overall effectiveness – 100%
To know more about our Services Call us at 9696086262 or email us at info@msplgroup.com
Also, you can visit our online website: www.mspwebstore.com
Follow us on FACEBOOK: https://www.facebook.com/mahavirsyspo...
LINKEDIN: https://www.linkedin.com/company/1453...
INSTAGRAM: https://www.instagram.com/mahavir_sys…
LICENSE CERTIFICATE: Envato Elements Item
=================================================
This license certificate documents a license to use the item listed below
on a non-exclusive, commercial, worldwide and revokable basis, for
one Single Use for this Registered Project.
Item Title: Corporate Music
Item URL: https://elements.envato.com/corporate-music-HZGUFM4
Item ID: HZGUFM4
Author Username: HimProduction
Licensee: Pranav Shah
Registered Project Name: MSP TV
License Date: November 20th, 2020
Item License Code: 9Y2V6MPWQL
The license you hold for this item is only valid if you complete your End
Product while your subscription is active. Then the license continues
for the life of the End Product (even if your subscription ends).
For any queries related to this document or license please contact
Envato Support via https://help.elements.envato.com/hc/en-us/requests/new
Envato Elements Pty Ltd (ABN 87 613 824 258)
PO Box 16122, Collins St West, VIC 8007, Australia
==== THIS IS NOT A TAX RECEIPT OR INVOICE ====
Видео Dr Amp Ep2_Three Types of UPS System Technologies канала MSP TV
Показать
Комментарии отсутствуют
Информация о видео
Другие видео канала
10 Important Considerations for Choosing Data Center Floor Tiles and Raised Floor Systems| MSP TVKey Data Center Innovations That You Need To Keep a Watch on | Daily DataCenter Ep-7The Secret Formula for Data Centre Electrical Power Distribution | DFD-EP5IT Policies of The UP government Got a Big Thumbs up | Daily Data Center Ep6Indian ISP 21 years of uninterrupted operations | Daily Data Center Ep-5Designing Data Center With Schneider ISX_DFD Ep-4An Ideal Data Center Needs Ideal Power Load | DFD_S2_EP3Billion Dollar Investments in India Market | Daily Data Center Ep-4Top 10 Criteria for Choosing an Ideal Data Center Location | Season 2-EP_2D For DataCenter_Season 2_PreviewTime To Take A Break | Dr Amp Ep-10India data center market will witness investments of USD 8 billion | Data Center Daily EP-37 Effects of Power Outage on Manufacturing Industry | Dr Amp Ep-9Top 10 Industries Affected by Power Failure| MSP TVCloud Services Reaching Spending Of Whopping 130Billion$ | DataCenter Daily Ep-2Well, Designed Products Are Key For Roller-Coaster of Success! | Dr Amp Ep-7INDIA IS THE RISING SUN IN DATA CENTER DEVELOPMENT MARKET | DataCenter Daily Ep-1UPS SYSTEMS ARE KEY TO LOWER OPERATING COST AND HIGHER ROI’S- Dr Amp Ep6TURN YOUR PRODUCTION LOSS INTO PROFIT WITH 3 SIMPLE SOLUTIONS! Dr AMP Ep-5Difference Between Volt & Watt - Dr Amp Ep-4Difference Between UPS & Inverter - Dr AMP Ep 3