The proper near Tankless piping for a Rinnai RUR unit
I've had so many questions from viewers on how to pipe in a RUR unit and numerous e mails and questions to trouble shoot the piping to a RUR unit.
I put together this video to show exactly how its done. Here I go over step by step the installation process of the near tankless piping. I did not glue or makeup the adaptors and the one check valve is 1"that's why there is blue tape on it.
The check valves you are to use are SPRING LOADED CHECK VALVES (NOT CLAPPER CHECK VALVES!!!!!!!!!!!)
THE VALVE AND DRAIN ARE FOR THE BLEEDING OF THE CIRCULATION LINE. Please do not forget to follow my video on bleeding the tankless!!
Mark the check valves in 4 different places with arrows to make sure you install them in the correct position. Remember both check valves with there arrows facing the tankless one on the cold water and the other on the circulation line.
The check valves I use come from Fergurson plumbing supply house.
ProFlo #PFXSCVF 3/4" spring check valve.
the valve and drain are a common type just make sure you use a ball valve for the isolation valve.
If you have any questions please e mail them to me at economyplmbg@aol.com
I hope you enjoy this video and again thanks for all the great comments I hope I've been helpful.
Mike
Видео The proper near Tankless piping for a Rinnai RUR unit канала The Rinnai Guy
I put together this video to show exactly how its done. Here I go over step by step the installation process of the near tankless piping. I did not glue or makeup the adaptors and the one check valve is 1"that's why there is blue tape on it.
The check valves you are to use are SPRING LOADED CHECK VALVES (NOT CLAPPER CHECK VALVES!!!!!!!!!!!)
THE VALVE AND DRAIN ARE FOR THE BLEEDING OF THE CIRCULATION LINE. Please do not forget to follow my video on bleeding the tankless!!
Mark the check valves in 4 different places with arrows to make sure you install them in the correct position. Remember both check valves with there arrows facing the tankless one on the cold water and the other on the circulation line.
The check valves I use come from Fergurson plumbing supply house.
ProFlo #PFXSCVF 3/4" spring check valve.
the valve and drain are a common type just make sure you use a ball valve for the isolation valve.
If you have any questions please e mail them to me at economyplmbg@aol.com
I hope you enjoy this video and again thanks for all the great comments I hope I've been helpful.
Mike
Видео The proper near Tankless piping for a Rinnai RUR unit канала The Rinnai Guy
Показать
Комментарии отсутствуют
Информация о видео
Другие видео канала
Proper gas piping and regulator set for a Rinnai tankless heaterHow to install Rinnai's thermal bypass valve on the RUR series heaters.Parameter settings and bleeding out heat exchanger and pump on a Rinnai RUR unit.Proper condensate drain piping for a Rinnai condensing unit.Tankless - What to know before you buyProper piping for a dedicated circulation line on a Rinnai RUR series unit.Installation and programing of Rinnai's MC-195T-US controller.Code 12 on a Rinnai tankless checking the flame rodsTankless install with recirculating pump and Bridge valve.Part (1) How to install a Rheem Tankless Water Heater (PROPANE) Model # RTG-70XLP-1Removal and cleaning of Rinnai's water flow turbineHow to wire and what wires to use for a Rinnai exterior tanklessRinnai RUR199 Annual Cleaning- Water Heaters NowBurner cleaning on a Rinnai non condensing tankless.How to install a Rinnai tankless heater.Proper vertical venting of a Rinnai tankless heater.Rinnai code 10, what causes it and how to fix itProper installation of a Rinnai condensing tankless water heater.Removal of a Rinnai inlet water filterHow to replace a water servo valve on a Rinnai R and RL non condensing heater.